Needle number: 40.
Specification: loose wire connector, 5 sets (0.3mm 2). Output type: bidirectional controlled silicon.
Output points: 16 points.
Load voltage: AC100-240.
Load current: 0.6A.
Connection mode: terminal row.
Common public end points: 8.
Structured text language is a programming language that describes a program with a structured description of the text HC-SFS102BG2 1/9.
It is a programming language similar to a high level language
HC-SFS102BG2 1/9 In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system.
Mainly used for other programming languages more difficult to achieve the user program HC-SFS102BG2 1/9.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation .
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified HC-SFS102BG2 1/9.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers. Poor visibility and operability. DC input points: 64 points.
Input voltage and current: 4/9mA, DC12/24V.
Response time: 107ms.
Positive pole sharing.
16 point /1 a public side.
Output points: 64 points.
Output voltage and current: DC12/24V, 100mA/1 point, 2A/1 common end.
Response time: (2I/O update time * 5) Ms.
32 point /1 a public side.
Output form: transistor output, leakage type.
40 pin connector x 4.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of thee PLC system in a haard wired way, and the timeliness is strong HC-SFS102BG2 1/9.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too gguarantee the timeliness HC-SFS102BG2 1/9.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
HC-SFS102BG2 1/9 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SFS102BG2 1/9&select=5