LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
HA-FF053
  • Brand: MITSUBISHI
  • Country: JAPAN
  • Name: Low inertia small capacity motor
  • Model: HA-FF053
  • Price: U.S.$ 720.34
MITSUBISHI HA-FF053
Power: 0.75kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor .
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table HA-FF053
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate HA-FF053.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor .
The installation of thermal relay, to avoid overheating and burn the braking resistor. The length of the line: 10M.
Relay type.
IP level: IP20.
Bending life: standard.
Encoder with cable (amplifier side); for HF-KP/HF-MP series. Input and output points: 512 points.
Input / output data points: 512 points HA-FF053.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delaay HA-FF053.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words HA-FF053. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
HA-FF053 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=HA-FF053&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Low inertia small capacity motor
HA-FF63
MITSUBISHI Low inertia small capacity motor HA-FF63
Motor series: low inertia, small capacit
MITSUBISHI
Low inertia small capacity motor
HA-FF053
MITSUBISHI Low inertia small capacity motor HA-FF053
Motor series: low inertia, small capacit
MITSUBISHI
servo motor
HA-FE43B
MITSUBISHI servo motor HA-FE43B
Type: HA-FE series. Rated output: 0.4KW.
MITSUBISHI
Low inertia small capacity motor
HC-KF053B
MITSUBISHI Low inertia small capacity motor HC-KF053B
Motor series: low inertia, small capacit