Analog input points: 2 channels
Voltage input range: DC0~10V, DC0~5V.
Current input range: DC4~20mA.
Resolution of 12 bit binary high precision analog input module.
Can be 2 channel voltage input, or current input. 15 inches.
Applicable model: GT27. Input and output points: 512 points.
Input / output data points: 512 points .
Program capacity: 14K GT10-50FMB.
Basic command processing speed (LD command) s:0.20
GT10-50FMB
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read GT10-50FMB.
Only when the program is scanned, the new state is read .
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction GT10-50FMB.
Instruction count.
Due to the adoption of centralized sampling .
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Protective film for 15 inch screen.
Transparent (frame: white), 5.
Applicable model: GT15. Cable length: 2.5m.
For motion controller CPU (A series, the main base system) and the connection between A7GT-CNB.
Applicable models: GT16, GT15, GT11. Accessories for 8.4 inch models.
Applicable models: GT16, GT15. Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermall expansion GT10-50FMB. Can be divideed into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy .
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply ccappacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set GT10-50FMB.