Input and output points: 14 points.
Power supply: DC24V.
Input points: 8 points.
Output points: 6 points.
Output form: transistor output (drain).
Power consumption: 19W.
Weight: 0.5KG.
Outline dimension: 90x90x86mm.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series FX5U-64MT/ESS.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application
FX5U-64MT/ESS
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points FX5U-64MT/ESS.
High speed operation.
Basic instructions: 0 . 21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.
Third generation standard model.
Easy to use integrated models and flexible scalability.
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control FX5U-64MT/ESS. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable meeasurement FX5U-64MT/ESS.
High speed,, smooth continuous analog output .
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulattedd according to the set conversion period FX5U-64MT/ESS.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
FX5U-64MT/ESS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX5U-64MT/ESS&select=5