MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 3.5kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: three phase AC400V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier .
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed
FX3U-1PG
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS FX3U-1PG.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version. Control axis: maximum 32 axes.
Compact size and space saving FX3U-1PG.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry .
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module.
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system.
In PC (Computer Personal) CPU.Output type: transistor source.
Output points: 32 points.
Load voltage: DC12/24.
Load current: 0.1A.
Connection: type D connector.
Common public end points: 32.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the currennt input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order FX3U-1PG.
So, sometimes also known as the order control.
And seqqueential control is divided into manual, semi-automatic or automatic FX3U-1PG.
And the control principle is decentralized, centralized and hybrid control three.
FX3U-1PG Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3U-1PG&select=5