Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (sink).
Power consumption: 11W.
Weight (kg):0.35.
Size (WxHxD) mm:60x90x87.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine FX3G-24MT/ESS.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc
FX3G-24MT/ESS.
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step FX3G-24MT/ESS.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. Used to prevent accidental shutdown switch.
Applicable model: hand held GOT. For MR-J2S-700A (4) /CP/CL or less.
Encoder set for HC-SFS; HC-LFS; HC-RFS; HC-UFS2000r/min; HA-LFS servo motor FX3G-24MT/ESS.
IP67; IP65. DC input points: 16 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
Positive pole sharing.
16 point /1 a public side.
Output points: 12 points.
Output voltage and current: DC12/24V, 0.5A/1 point, 3.2A/1 common end.
Response time: 2ms.
8 point /1 a public end, 4 point /1 a public end.
Output form: transistor output, leakage type.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a haard wired way, and the timeliness is strong FX3G-24MT/ESS.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too gguarantee the timeliness FX3G-24MT/ESS.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
FX3G-24MT/ESS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3G-24MT/ESS&select=5