MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 7.0kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: three phase AC200V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier .
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed
FX2NC-4DA
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS FX2NC-4DA.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version. Data format: ASCII.
Data bits: 7.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing FX2NC-4DA.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components.
This feature makes the main station of the data acquisition and control with more flexibility.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII. Function: high performance and low price in the middle end model.
Picture size: 8.4 inches.
Resolution: VGA.
Display: TFT color.
Panel color: white.
Power type: DC24V.
Middle end model of high performance and low price.
GT25 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface.
Even in the log, script, alarm, soft component data transmission, such as high load processing period, but also to achieve smooth operation of the screen.
Connect GOT front USB interface and computer,
Can be through the FA, the GOT machine programming, start and adjust the operation,
Save the trouble of opening the control cabinet and changing the cable.
1, USB interface: device USB machine (Mini-B USB)
Can connect to the computer to transfer data.
2, USB interface: host USB (USB-A)
USB data can be transmitted through the USB memory or read log data, such as the GOT data, but also can be connected to the use of the mouse, keyboard.
3, the extension of the interfface
Communication module aand optional module can be installed FX2NC-4DA.
4, Ethernet interface
Up to 4 different manufacturers can be connected at the same time
FA machine.
5, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
6, RS-422/485 interffacce
Can be connected to a variety of FA machines, bar code reader FX2NC-4DA.
7, SD memory card slot
Can save alarm and log data, such as a large number of data.
FX2NC-4DA Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX2NC-4DA&select=5