FX2N-16MT-DSS
MITSUBISHI FX2N-16MT-DSS
Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points.
Output points: 40 points.
Output type: relay.
Power consumption: 70VA.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FX2N-16MT-DSS
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program FX2N-16MT-DSS.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard .
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Application: Q series.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1 FX2N-16MT-DSS.
Security input points: 1 .
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file storedd on the SD memory cardd can be sent to the FTP server FX2N-16MT-DSS.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do noot have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution FX2N-16MT-DSS.
FX2N-16MT-DSS Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FX2N-16MT-DSS&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
High speed counting module
FX2N-1HC
MITSUBISHI High speed counting module FX2N-1HC
Signal level: the DC5V, 12V, and 24V dif
MITSUBISHI
PLC
FX2N-16MT-001
MITSUBISHI PLC FX2N-16MT-001
Max input / output points: 16 points. Su
MITSUBISHI
PLC
FX2N-64MT-DSS
MITSUBISHI PLC FX2N-64MT-DSS
Max input / output points: 64 points. Po
MITSUBISHI
PLC
FX2N-16MR-001
MITSUBISHI PLC FX2N-16MR-001
Max input / output points: 16 points. Su