Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command): with 1 s coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process . When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read
FR-BAL-H0.4K
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program FR-BAL-H0.4K.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators FR-BAL-H0.4K.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption: 25w.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Paassword protection, using a eight digit password to protect your program FR-BAL-H0.4K.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time FR-BAL-H0.4K.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
FR-BAL-H0.4K Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-BAL-H0.4K&select=5