Master / local station sharing.
Corresponding Ver2 CC-Link.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time .
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module
FR-A840-02600-2-60
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) FR-A840-02600-2-60. Board module installation location: QS series power module mounting slot .
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards FR-A840-02600-2-60.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.2kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: single phase AC200V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier.
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed.
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compaatibility with MR--J3-B FR-A840-02600-2-60.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS.
Security functions are connected to the CN8 interface through an external securityy ccircuit to increase the MR-J3-BS driver security FR-A840-02600-2-60.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version.
FR-A840-02600-2-60 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-A840-02600-2-60&select=5