Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode .
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time
FA-CBL20FMV To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost FA-CBL20FMV.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs FA-CBL20FMV.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control). 48MB extended memory.
Applicable model: GT15. 3C-2V/5C-2V coaxial cable.
Double circuit.
MELSECNET (II) (Master / local station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the systemm FA-CBL20FMV.
MITSUBISHI PLC initiallization procedure . After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program arre:: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc FA-CBL20FMV. .