LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
F2-232CAB-2
MITSUBISHI F2-232CAB-2
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 4 points / a public end F2-232CAB-2.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points F2-232CAB-2
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process F2-232CAB-2.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Twisted pair cable.
Single bus.
MELSECNET/B (Master / local station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the systemm F2-232CAB-2.
MITSUBISHI PLC initiallization procedure . After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program arre:: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc F2-232CAB-2. .
F2-232CAB-2 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F2-232CAB-2&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
RS-232C cable for computer
F2-232CAB-2
MITSUBISHI RS-232C cable for computer F2-232CAB-2
Length: 3m. Specification: half pitch 14
MITSUBISHI
RS-232C cable for computer
F2-232CAB
MITSUBISHI RS-232C cable for computer F2-232CAB
Length: 3m. Specification: D-su 25 pin
MITSUBISHI
Connecting cable
F2-232CAB-1
MITSUBISHI Connecting cable F2-232CAB-1
PC-9800 computer D-SUB 25 pin
MITSUBISHI
Connecting cable
FX-232CAB-2
MITSUBISHI Connecting cable FX-232CAB-2
PC-9800 computer half pitch 14 pin