AY15CEU
  • Brand: MITSUBISHI
  • Country: JAPAN
  • Name: Relay output module
  • Model: AY15CEU
  • Price: 0
  • >
MITSUBISHI AY15CEU
Output points: 16 points.
Voltage: DC24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With heat protection.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling . Focus on the output signal to refresh AY15CEU.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AY15CEU
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AY15CEU.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive AY15CEU.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. The most appropriate temperature regulation control (PID control) is possible,
In order to control the PID does not need to specify a special command.
In addition, according to the automatic regulation function,
The automatic setting of PID number is possible.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the channge of the external output siignal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse oof the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AY15CEU AY15CEU.
This phenomenon is called the I/O delay time effect.
AY15CEU Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AY15CEU&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Relay output module
AY13
MITSUBISHI Relay output module AY13
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11EEU
MITSUBISHI Relay output module AY11EEU
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY13E
MITSUBISHI Relay output module AY13E
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11AEU
MITSUBISHI Relay output module AY11AEU
Output points: 16 points. Voltage: DC24V