MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.75kw.
Interface type: CC-Link communication type (built-in positioning function).
Power specification: single phase AC200V.
Positioning operation by setting position and rotational speed data in the positioning table and receiving the start signal from the main controller AJ65SBTC1-32DT2.
The setting of the position and speed of the positioning table, as well as the start and stop operation can be completed through CC-Link communication
AJ65SBTC1-32DT2
By using the MR-J3-D01 extension IO unit, the DI/O instruction can be used to select and locate the table.
(CC-Link can not be used for MR-J3-D01 communications) AJ65SBTC1-32DT2.
With built-in positioning function of the servo amplifier, can be set through the CC-Link communications and speed data . (corresponding to the CC-Link version: Ver.1.10)
Can be achieved through the CC-Link communications to start, stop and monitoring and other operations.
Serial communication reduce wiring.
Distributed servo control system can be built by CC-Link communication.
The parameters of unit MR-PRU03 (optional) the parameter setting, operation and monitoring more convenient AJ65SBTC1-32DT2.
The servo amplifier can be used for speed control operation.
When the two stations are occupied, the speed can be set directly by the remote register. Output type: relay.
Output points: 16 points.
Load voltage: AC120/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 8.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line, inn accordance with thee functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the compllicaated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced AJ65SBTC1-32DT2 AJ65SBTC1-32DT2.
AJ65SBTC1-32DT2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=AJ65SBTC1-32DT2&select=5