LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
AJ65SBTB1-32KDT216
MITSUBISHI AJ65SBTB1-32KDT216
For common cathode input module (3 line type).Power: 220kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Output points: 4 points .
Output voltage and current: DC12/24V AJ65SBTB1-32KDT216.
Output response time: 2ms.
4 point /1 a public side.
Output form: transistor output, leakage type AJ65SBTB1-32KDT216
16 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations AJ65SBTB1-32KDT216.
MITSUBISHI PLC initialization procedure . After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc AJ65SBTB1-32KDT216. .
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
Analog input voltage: -.
Digital output value: -.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detecction
Works3 GX caan be used to easily set the critical value of the input and output signals AJ65SBTB1-32KDT216.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Model withh "" -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current AJ65SBTB1-32KDT216.
AJ65SBTB1-32KDT216 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AJ65SBTB1-32KDT216&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Transistor output module
AJ65SBTB1-32T
MITSUBISHI Transistor output module AJ65SBTB1-32T
Output type: transistor output, drain ty
MITSUBISHI
Transistor output module
AJ65SBTB1B-16TE1
MITSUBISHI Transistor output module AJ65SBTB1B-16TE1
Output type: transistor output, source.
MITSUBISHI
Input module
AJ65SBTB1-32D5
MITSUBISHI Input module AJ65SBTB1-32D5
Input type: DC input, positive pulic en