Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 1.0kw.
Interface type: SSCNET type III fiber communication.
Special specification: suitable for linear servo motor.
Power specification: three phase AC200V AJ65BT-G4.
More advanced real-time automatic tuning by setting response values,
Including the position gain and the gain of speed, all the gain can be adjusted automatically
AJ65BT-G4
32 segment response level can be set.
Advanced vibration suppression control.
An optimal vibration control filter value is automatically set by the automatic tuning function to effectively suppress the vibration of the 100Hz frequency that occurs when the driving part stops AJ65BT-G4.
The automatic tuning function can effectively restrain the vibration of the end of the mechanical arm and reduce the residual vibration in the machine. Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0 AJ65BT-G4. 2.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of .
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric couplerr AJ65BT-G4.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words AJ65BT-G4. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
AJ65BT-G4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=AJ65BT-G4&select=5