8 channel.
Input: DC-10~10V.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~1200; 0~16000; -16000~16000.
Conversion speed of 80 s/1 channel.
18 point terminal station.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications .
Can also meet the needs of high speed, high precision control A9GT-QJ71LP23.
Most suitable analog modules for high speed conversion control
A9GT-QJ71LP23
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs A9GT-QJ71LP23.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields A9GT-QJ71LP23.
Can also be used in combination with the CPU module to achieve appropriate control.Power: 45kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) The A1SP60 pulse capture module is a 16 point DC24V input module,
Can be used as a general inputt module,
Can also be uused as a pulse capture module,
Pulse capture function makes the input signal width in the sequence can be as short as 0 A9GT-QJ71LP23.5ms,
Once there is a pulse signal input, the state is memory,
A1SP60 to ensure that the control process at least once again to coontrol the state of the memory of the operation,
Input can be set to 4 blocks,
Each block can be set to a general function or pulse capture function A9GT-QJ71LP23.
A9GT-QJ71LP23 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A9GT-QJ71LP23&select=5