1 axis servo amplifier.
MITSUBISHI general AC servo amplifier MELSERVO-J4 series.
Rated output: 2.0kw.
Interface: General purpose.
Power supply: three phase AC200V.
Special specification: full closed loop control 4 wire / device end encoder ABZ phase input corresponding support function security unit, support positioning mode .
Servo amplifier supporting universal interface A3AMCA-96.
Servo amplifier for universal interface
A3AMCA-96
Speed / torque control of position control and analog voltage command can be carried out by using pulse train command.
Support Max instruction pulse frequency 4 Mpulses/s.
2 low frequency vibration can be suppressed at the same time by supporting the seismic algorithm of 3 inertial equipment A3AMCA-96.
Configurator2 MR to achieve convenient adjustment.
Effectively restrain the low frequency aftershock effect produced by the front end of the boom or the main body of the device 100Hz.
Can effectively shorten the time to control the stability of the aftershock.
In the XY design of trajectory control, improve the accuracy of arc track.
At the same time, it can effectively control the phenomenon of quadrant protrusion caused by the rotation direction of the servo motor, which is caused by friction and twisting A3AMCA-96. Input points: 16 points.
Voltage: DC5/12/24V.
Current: 5.5/3/6mA.
Response time: 3ms.
8 points / a common end.
Positive / negative sharing.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selectionn,
Under the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A3AMCA-96.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A3AMCA-96.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
A3AMCA-96 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3AMCA-96&select=5