Function: CPU module.
Input and output points: 32 points.
Power supply capacity (DC5V power): 720mA.
Power supply capacity (DC24V service power supply): 500mA.
Input / output mode: DC input (drain) / transistor (drain).
Input points: 16 points.
Output points: 16 points.
Expansion module is more compact, more suitable for small devices!
Small body on the collection of many functions A3ACPU.
FX5UC can be connected to the expansion module, compact and convenient,
Suitable for all kinds of small equipment
A3ACPU
Through the rich conversion module,
Can freely connect FX5 and FX3 expansion devices. Input points: 16 points.
Input voltage and current: 120V ~ 6mA AC100.
Input response time: 30ms A3ACPU.
16 point /1 a public side .
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay.
8 point /1 a public side.
50 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A3ACPU.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the acttion principle of the solenoidd valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A3ACPU A3ACPU.
A3ACPU Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3ACPU&select=5