QnA/ACPU bus connection.
1 joint.
Applicable models: A985 (-V) /975/970/960/956 (W) GOT. Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs A2USCPU-S1.
High speed communication capable of communicating with 1Gbps
A2USCPU-S1
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller A2USCPU-S1.
Status of IE CC-Link field network can be confirmed by Works2 GX .
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.Enter 32 points or 32 points;
Divided into 16 points, 16 points out of the output A2USCPU-S1.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection . Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature conntrol stability of extrusiion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling A2USCPU-S1.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrroll (heating and cooling) mode A2USCPU-S1.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.