Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater .
Event entry point: 2.
Transfer output: - 82375-0700 SGEY-365-2-3050SP-0.
Remote SP:4 to 20mA input.
Communication: -
82375-0700 SGEY-365-2-3050SP-0
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved 82375-0700 SGEY-365-2-3050SP-0.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV 82375-0700 SGEY-365-2-3050SP-0.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: Standard models.
Connecting method: Wire-saving connector *1.
Model: NPN output.
Applicable wire-saving connector(sold separately):
Type,Master connector, Slave connector; Model, E3X-CN21, E3X-CN22.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximaately 20 years 82375-0700 SGEY-365-2-3050SP-0.
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even fforr low-reflective objects and large objects 82375-0700 SGEY-365-2-3050SP-0.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit.
82375-0700 SGEY-365-2-3050SP-0 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=82375-0700 SGEY-365-2-3050SP-0&select=5