When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Ontology: terminal type, analog input type .
Category: control output 2 point type (power supply AC100 ~ 240V) 74008-3612 UMY10-3612.
Shell color: black
74008-3612 UMY10-3612
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use 74008-3612 UMY10-3612.
Event input points: - .
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type 74008-3612 UMY10-3612.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Structure: Relays with Plug-in Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joineed the series 74008-3612 UMY10-3612.
The lineup also includes models that are compliant,
with the LR and VDE safety standards .
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 11000/110 VDC) 74008-3612 UMY10-3612.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).
74008-3612 UMY10-3612 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=74008-3612 UMY10-3612&select=5