Control power supply voltage: 24 VDC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V .
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) 70156-4551 MS46SR-20-1130-Q2-1.
Detect three-phase AC current for under and/or overcur,
rent using current converter
70156-4551 MS46SR-20-1130-Q2-1
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T) 70156-4551 MS46SR-20-1130-Q2-1.
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection .
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also 70156-4551 MS46SR-20-1130-Q2-1.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) .
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type of input: AC voltage input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some modells aree not equipped with 70156-4551 MS46SR-20-1130-Q2-1.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub presssuure gauge for monitoring the operation trend 70156-4551 MS46SR-20-1130-Q2-1.
External event input can be applied to a variety of measurement and identification situations.
DeviceN
70156-4551 MS46SR-20-1130-Q2-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70156-4551 MS46SR-20-1130-Q2-1&select=5