Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Center roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection 70156-1629 MS46LR-30-1045-Q1-3.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
70156-1629 MS46LR-30-1045-Q1-3
Cable lengths of 3 and 5 m available on standard models 70156-1629 MS46LR-30-1045-Q1-3.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: output module.
Insulation mode: three end two-way photoelectric switch 70156-1629 MS46LR-30-1045-Q1-3.
Action indicator: there.
Zero trigger function: No.
Applicable load of output: AC100 2A ~ 240V .
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)I/O Control UnitNumber of beams: 68.
Protective height: 2040mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,,
to set functions 70156-1629 MS46LR-30-1045-Q1-3.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions 70156-1629 MS46LR-30-1045-Q1-3.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
70156-1629 MS46LR-30-1045-Q1-3 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70156-1629 MS46LR-30-1045-Q1-3&select=5