Type of input: AC voltage input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table 70156-1393 MS46SR-30-1390-Q1-1.
Action determine the color, can switch the green / Red 2 kinds of color display
70156-1393 MS46SR-30-1390-Q1-1
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations 70156-1393 MS46SR-30-1390-Q1-1.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm .
ULOpen circuit: voltage, no voltage, DC circuit breaker.
Appearance: R2 shell, also has F4 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7 70156-1393 MS46SR-30-1390-Q1-1. 5A cos (AC 250V maximum diameter =0 . 4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times.
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 poinnt traansfer output and remote SP input, suitable for a wide range of applications 70156-1393 MS46SR-30-1390-Q1-1.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperratture controller is connected to each other by using the component communication 70156-1393 MS46SR-30-1390-Q1-1.
A new type of proportional control allows you to control the valve.
70156-1393 MS46SR-30-1390-Q1-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70156-1393 MS46SR-30-1390-Q1-1&select=5