Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 5VDC.
Output current: 3.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market .
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time
70069-1003 SCL10 Long distance detection for various applications.
The measuring range can be simply set with the setting plug with the temperature correction function 70069-1003 SCL10.
Because it is ultrasonic and can not be affected by the color .
And K3NX type digital panel meter combination, can be a variety of control. Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with 70069-1003 SCL10.
Cylindrical 16-dia. Body.
Miniature design of 28 . 5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. E32-T12L type: special beam type; long range / high function,
Specialty: diameter 3 cylinder,
Shape / detection distance (mm): 1700; 1330; 870 (350),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 1.4 (0.01),
Fiber element for meeting diversified needsSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV 70069-1003 SCL10.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation 70069-1003 SCL10.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
70069-1003 SCL10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=70069-1003 SCL10&select=5