Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 2000mm; B, 1750mm.
Output use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) .
Shell color: black 61F-G1PD AC220.
Control output: linear voltage output.
Control mode: standard or heating cooling
61F-G1PD AC220
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved 61F-G1PD AC220.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors 61F-G1PD AC220.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV .
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Connection method: Pre-wired.
Cable length: 2 m.
Sensing distance: 100 ± 35 mm.
Model: PNP output.
A CMOS Laser Sensor That’s.
Optimum for Simple Measurements.
A resolution of 0.002 mm that’s suitable for simple measure ments.
Stable measurements for any type of workpiece.
Models available with four different distance specifications.
Long-distance model for up to 1,000 mm. Specifications: Inputs; NPN (+ common); 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be colleected without affectinng the productivity,
of the control system 61F-G1PD AC220.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating informattioon 61F-G1PD AC220.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.
61F-G1PD AC220 Operation manual/Instructions/Model selection sample download link: