C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD004(3G2A5-AD004).
Input: 2 pts.
Specification: -10~+10V.Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 .
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2 44542-2210 HP2008-11H.
Auxiliary output: None
44542-2210 HP2008-11H
Functions: burnout Heater alarm, None; Event inputs, None .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel 44542-2210 HP2008-11H.
Terminal: Screw-less clamp .
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design 44542-2210 HP2008-11H.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Reliable reading of all kinds of two-dimensional code printed directly on a variety of materials.
Visual display of two-dimensional code reading.
Wide field of view.
Direct display customization.
Rich liquid crystal display mode. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor inpput, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified 44542-2210 HP2008-11H.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipppedd with the sub pressure gauge for monitoring the operation trend 44542-2210 HP2008-11H.
External event inputs can be applied to a variety of measurement and identification
44542-2210 HP2008-11H Operation manual/Instructions/Model selection sample download link: