Appearance: Key-type Selector Switch A22K.
Number of notches: 2 notches.
Reset method: Manual.
Output: SPST-NC + SPST-NC.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Socket Unit.
Finger protection mechanism on Switch Unit provided as a standard feature .
Use 25-dia. ring to install in 25-dia 44530-0710 SM30-MCK10. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round type) crimp terminals
44530-0710 SM30-MCK10
IP65 oil resistance. Appearance: Square/Projection type LED lighting,
(without Voltage Reduction Unit) A22L-D.
Output: SPST-NO + SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC 44530-0710 SM30-MCK10.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue) .
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature 44530-0710 SM30-MCK10.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type .
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Cable sheath material: LSZH.
Cable color: Yellow.
Cable length: 0.5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: double alarm.
Output: voltage output (solid state relay driver).
Digital universal dual display electronic temperature controller.
DIN 48 * 48mm manual automatic tuning (Auto-tuning Manual) PID control.
Double alarm / single alarm and temperature resistance antibody species rich.
Relay / solid state relay (SSR drive) series.
To prevent misuse function.Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communicaation 44530-0710 SM30-MCK10.
The usee of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) .
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthee basic function is complete 44530-0710 SM30-MCK10.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
44530-0710 SM30-MCK10 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44530-0710 SM30-MCK10&select=5