Function name: three phase 400V.
Power: 0.75KW.
Maximum output voltage: three phase 380 ~ 480VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show 3G3JX-AE004.
Standard configuration has RS485 interface, Modbus bus communication function
3G3JX-AE004
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action 3G3JX-AE004.
Software setting operation mode, no need to connect the control line can be used for speed control. Model: C500-CN531.
Cable length: 50 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
C200H Accessory Programming Console Adapter C200H-BP002.Type: 1a1b welding terminal.
Shape: rectangle.
Type: General load.
Action: instantaneous action (auto recovery) 3G3JX-AE004.
With lamp: no light.
Operation Department color: black.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for Monitoring 3-phase Power Suppllies 3G3JX-AE004.
for Industrial Faccilities and Equipment .
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resisstiive load) 3G3JX-AE004.
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator.
3G3JX-AE004 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G3JX-AE004&select=5