Type: H7CX-A Series.
Classification: Preset counter.
Configuration: 1-stage preset counter; Total and preset counter.
External connections: 11-pin socket.
Settings: 1-stage.
Display digit: 4 digits.
Outputs: Contact output (SPDT).
Power supply voltage: 12 to 24 VDC/24 VAC.
Ultra-compact Counter Provides More,
Complete Functionality 3G3IV-PERF150WJ201.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals)
3G3IV-PERF150WJ201
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability 3G3IV-PERF150WJ201.
New set value limit and counter functions have been added .
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/M12 Straight).
Cable length: 1 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks 3G3IV-PERF150WJ201. Name: CS1D Duplex Unit .
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Not supported.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Number of notches: 3 notches.
Output: DPDT.
Reset method: Manual.
Key release position: Right.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28.5 mm below panel.
Wide range of switching capacity from standard to microload.
Oil-resistant IP65 models. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three coontact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC 3G3IV-PERF150WJ201.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reeliability 3G3IV-PERF150WJ201.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.