Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485
3G3FV-A4055-CUE
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices 3G3FV-A4055-CUE.
The compact modular structure enables construction of temperature,
systems optimally suited to the application .
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements 3G3FV-A4055-CUE.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. Socket body.
Representative examples of applicable models.
Timer: H3Y series; H3YN series; H3Y (N) -4-B.
Pole number: 4.
Socket for MY relay, G2R-S relay.
Save hours of Push-InPlus terminal type to add product series.
Using Plus Push-In terminal, compared with the previous screw terminals,
Save wiring time (compared with the previous screw terminals, can shorten the wiring time of about 60%*) 3G3FV-A4055-CUE. .
Screw will not loose, to achieve maintenance free.
The insertion force is small, the drawing strength is big, and the wiring time is saved, and the high reliability is simultaneously considered.
When connecting multiple strands, the use of non - hoolding mechanism,
Insert a word screwdriver to keep it 3G3FV-A4055-CUE.
2 wires can be inserted in each terminal.
DIN guide rail installation, screw mounting common.
3G3FV-A4055-CUE Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=3G3FV-A4055-CUE&select=5