Security module.
Maximum applicable motor capacity: 0.1kw.
Power supply voltage: single phase AC100V.
Interface: MECHATROLINK- III communication command type (linear servo motor).
Design sequence: A.
Hardware specifications: paint.
Matching (software): no matching (standard).
Matching (parameters): no matching (standard) .
Optional module: security module SGDV-2R8A01B002FT001.
European EC standards: Based on the integration of mechanical instructions standard ISO13849-1 EN,
Security module with individual standard 61800-5-2 IEC specified security function
SGDV-2R8A01B002FT001
Through the combination of the SGDV servo unit, the best safety design of the mechanical system is realized SGDV-2R8A01B002FT001.
Suitable for AC servo drive, with the following safety features specified in the international standard IEC61800-5-2 (Japan''s first) .
Can easily achieve the best security design of mechanical systems.
Torque Off Safe (STO)
Stop Safe 1 (SS1)
Stop Safe 2 (SS2)
Limited Speed Safely (SLS)
Equipped with 2 security functions, can be set (distribution) security functions.
In addition, the monitoring time and other items can be changed through the parameter SGDV-2R8A01B002FT001.
With the use of the servo unit with a security module, so that the system can be simplified and miniaturized. Security module.
Maximum applicable motor capacity: 0.2kw.
Power supply voltage: three phase AC200V.
Interface: analog voltage, pulse sequence type (linear servo motor).
Design sequence: B.
Hardware specifications: paint.
Matching (software): no matching (standard).
Matching (parameters): no matching (standard).
Optional module: security module.
European EC standards: Based on the integration of mechanical instructions standard ISO13849-1 EN,
Security module with individual standard 61800-5-2 IEC specified security function.
Through the combination of the SGDV servo unit, the best safety design of the mechanical system is realized.
Suitable for AC servo drive, with the following safety features specified in the international standard IEC61800-5-2 (Japan''s first).
Can easily achieve the beest security dessign of mechanical systems SGDV-2R8A01B002FT001.
Torque Off Safe (STO)
Stop Safe 1 (SS1)
Stop Safe 2 (SS2)
Limited Speed Safely (SLS)
Equipped with 2 security functions, can be set (distribution) security functions.
In addition, the monitoring time and other itemms can be changed through the parameter SGDV-2R8A01B002FT001.
With the use of the servo unit with a security module, so that the system can be simplified and miniaturized.
SGDV-2R8A01B002FT001 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGDV-2R8A01B002FT001&select=5