Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Positive common end use. Output type: transistor source / drain type.
Output points: 8 points.
Load voltage: DC5/12/24/48.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF MR-J4-40A1.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC
MR-J4-40A1
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MR-J4-40A1.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Enter 32 points or 32 points;
Divided into 16 points, 16 points out of the output.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection MR-J4-40A1. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 7.0kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: three phase AC200V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier.
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed.
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control systeem MR-J4-40A1.
Compatibility with MR--J3-B .
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS.
Security functions are connected to the CN8 interface through an external securityy ccircuit to increase the MR-J3-BS driver security MR-J4-40A1.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version.
MR-J4-40A1 Operation manual/Instructions/Model selection sample download link: