Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal .
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called
MR-J3-60B-RJ080W
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MR-J3-60B-RJ080W.
Communication protocol is a standard Modbus protocol or custom protocol. Input and output points: 10 points.
Power supply: DC24V.
Input points: 6 points.
Output points: 4 points.
Output form: relay output.
Power consumption: 6W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features MR-J3-60B-RJ080W.
Special adaptor and function expansion board can be installed and used FX3 series .
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 3.7KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
SSpeed control methodd of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs off closure MR-J3-60B-RJ080W MR-J3-60B-RJ080W.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.
MR-J3-60B-RJ080W Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3-60B-RJ080W&select=5