Servo motor series: low inertia, medium / high power.
Rated output: 22.0kw.
Rated speed: 1500r/min.
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Features: low inertia has low medium and high speed three models, suitable for different applications as a standard, 30KW and above servo motor can be installed flange or bracket MR-J3-60B-RJ006.
IP level: IP44.
Application example:
1, injection molding machine
MR-J3-60B-RJ006
2, semiconductor manufacturing equipment.
3, large material handling system.
4, stamping machine.
Abundant motor product line can optimize the performance of the machine.
Has a rich motor product line including a rotary servo motor, linear servo motor and direct drive motor MR-J3-60B-RJ006. Input type: DC input, negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, source.
Output points: 8 points.
OFF leakage current: 0.3mA.
Output protection function.
Rated load voltage / current: DC24V/1.0A.
External connection: /2 line 2~4 line type MR-J3-60B-RJ006.
Waterproof connector type.
Strong waterproof type of IP67 protection grade .
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. RS-232C 1 channel, RS-422 1 channel.
Transfer speed: 0.3-19.2kbps.
Multi station communication network function (Master / local station).
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / ooutput device relatedd to the MITSUBISHI PLC,
To determine the I/O PLC points MR-J3-60B-RJ006.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control reequirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book MR-J3-60B-RJ006.
MR-J3-60B-RJ006 Operation manual/Instructions/Model selection sample download link: