Type: 18 point terminal.
Input type: DC input, the common cathode / negative public end sharing.
Input points: 16 points.
Rated input voltage / current: DC24V (6mA).
External connection: 1 wire.
Can be on the remote /O I module, analog module, high-speed counter module free extension of input and output points .
The analog input module can be extended, and the sampling time of the analog and digital conversion values can be controlled by the external input signal
HA-LP15K2 (trigger conversion function)
Scalable high-speed counter module, ON/OFF control in the implementation of accurate cycle. (cam switching function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices HA-LP15K2.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station HA-LP15K2. Master station module for CC-Link.
FX2N-16CCL-M is the PLC CC-Link as the FX master module.
Up to 7 remote I/O stations and 8 remote stations can be connected to the main station.
Using the CC-LINK FX2N-32CCL interface, you can install PLC FX as CC-LINK remote device station to connect.
In addition, through the connection of various equipment manufacturers, can be applied to a variety of purposes of the system.
The most suitable for production lines and other equipment control. 16 channels.
Input: DC-10 ~ 10V, DC-20 ~ 20mA.
Output (resolution): -4000 ~ 4000, -2000 ~ 2000
Transformation speed: 1ms (sample processing) /7ms (direct access processing).
38 point terminal station.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal.
It is through the input interface circuit to the external switch signal intoo PLC internal can accept tthe digital signal HA-LP15K2.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithhmeetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process HA-LP15K2.
HA-LP15K2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HA-LP15K2&select=5