Close to input / output: 8 DC input or keyboard: 64 DC input, 16 transistor output.
Applicable model: A985/975/970/A960GOT (-B). Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 40K.
Increase the speed of a constant cycle interrupt program .
Perform a minimum interval constant period interrupt program can be shortened to 50 s,
Programmable logic controller can read more high-speed signals
HA-LF37K1M4
In addition, the interrupt routine can be set priority, and the interrupt program with high priority is executed when the interrupt processing is interrupted.
Therefore, when the signal is read at a high speed, the program can read the signal from the constant cycle of the conventional input module +CPU module HA-LF37K1M4.
Soft element / label area for easy processing
The extended SRAM card is installed on the programmable controller CPU module,
Soft element / label storage area with up to 5786K words.
The expansion area is connected to the memory of the built-in CPU module,
The range of soft components / labels can be freely distributed HA-LF37K1M4.
Therefore, it can be easily programmed without taking into account the boundaries of each storage area.
In addition, can also use the SD memory card processing records data, database data, such as large capacity data. External input / output interface unit2 axes.
2 axis linear interpolation.
Control unit: pulse, mm, inch, degree.
Determine the location of the number of data: 400/1 axis.
40 pin connector.
Control mode: position automatic acceleration and deceleration time: 64-4999ms pulse train output.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system.
Mainly used for other programming languages more difficult to achieve the user program.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the complicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced.
A1SD75 series components show MITSUBISHI in manufacturing and design CNC,
Integraated technical experiencee in the aspects of frequency converter, servo system and PLC HA-LF37K1M4.
These components have a wealth of features that are sufficient to meet the highest requirements in the application of positioning control.
Up to 3 axis linkage operation,
In low cost mootiion control applications, this component can be used to control the operation of a multi - to 3 axis, which can be used to account for only one slot HA-LF37K1M4.
HA-LF37K1M4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HA-LF37K1M4&select=5