LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
FR-D720S-1.5K
MITSUBISHI FR-D720S-1.5K
Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end .
36 point terminal station FR-D720S-1.5K.
With short circuit protection.
With the surge absorber FR-D720S-1.5K
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points FR-D720S-1.5K.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process FR-D720S-1.5K.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching ssignal, the fault signaal transmission device, brake signal and fan fault signal FR-D720S-1.5K.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points FR-D720S-1.5K.
FR-D720S-1.5K Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-D720S-1.5K&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.1K
MITSUBISHI Single phase 200V inverter FR-D720S-0.1K
MITSUBISHI inverter FR-D720S series. Vol
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.4K
MITSUBISHI Single phase 200V inverter FR-D720S-0.4K
MITSUBISHI inverter FR-D720S series. Vol
MITSUBISHI
3 phase 200V converter
FR-D720-2.2K
MITSUBISHI 3 phase 200V converter FR-D720-2.2K
MITSUBISHI inverter FR-D720 series. Volt
MITSUBISHI
Single phase 200V inverter
FR-D720S-0.75K
MITSUBISHI Single phase 200V inverter FR-D720S-0.75K
MITSUBISHI inverter FR-D720S series. Vol