LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
FA-TH16YRA11S
MITSUBISHI FA-TH16YRA11S
A 20 pin connector is installed on one side of the loose line.
Length 5M. Cable length: 5m.
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-SFS; HC-LFS; HC-RFS; 2000r/min HA-LFS; HC-UFS servo motor.
-H products have a long flex life. Power: 280kw.
Voltage: 400V.
The power factor of the input power factor is up to 0 . 99 and above (100% load) FA-TH16YRA11S.
Can be connected to multiple inverters, to achieve a common DC bus mode FA-TH16YRA11S
Equipped with standard power retrogradation function. The length of the line: 2M.
IP level: IP65.
Bending life: high bending life.
Electric motor power supply cable for HF-KP/HF-MP series (motor shaft with side extraction). Power: 7.5kw.
Voltage: 200V FA-TH16YRA11S.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter .
Motor suitable for 5.5 to 37kW. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 2.2kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FA-TH16YRA11S.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For tthe variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FA-TH16YRA11S.
The general inverter is 1520 times inverter price.
The main device caalled "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FA-TH16YRA11S. "
FA-TH16YRA11S Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FA-TH16YRA11S&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Terminal module
FA-TH16X100D31L
MITSUBISHI Terminal module FA-TH16X100D31L
Can e isolated to otain DC24/48/100V,
MITSUBISHI
Terminal module
FA-TH16YRAC20S
MITSUBISHI Terminal module FA-TH16YRAC20S
Can e isolated from the output of the p
MITSUBISHI
Terminal module
FA-TH16X100A31
MITSUBISHI Terminal module FA-TH16X100A31
Can e isolated to otain DC24/48/100V,
MITSUBISHI
Terminal module
FA-TH16X24D31
MITSUBISHI Terminal module FA-TH16X24D31
Can e isolated to otain DC24/48/100V,