FA-TB161ACC2
MITSUBISHI FA-TB161ACC2
Drive: MR-H_ACN series built-in positioning function.
Rated output: 1.0KW.
In servo drive speed closed loop,
Rotor speed measurement accuracy is very important to improve the dynamic and static characteristics of the speed control loop.
In order to seek the balance between measurement precision and system cost, incremental photoelectric encoder is generally used as the speed measuring sensor,
The corresponding method is M/T velocity measurement FA-TB161ACC2
Although the M/T measurement method has a certain measurement accuracy and a wide range of measurement,
But this method has its inherent defects,
Mainly includes: the measurement period must be detected at least one complete encoder pulse, limiting the minimum detectable speed FA-TB161ACC2.
2 control system for speed control of the timer switch is difficult to maintain synchronization,
Can not guarantee the accuracy of measurement in the situation where the speed change is larger.
Therefore, it is difficult to improve the speed tracking and control performance of servo drive by using the traditional speed loop design method FA-TB161ACC2. "Accessories for 10.4 inch models .
Applicable models: GT16, GT15. "Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
UUser program storage cappacity: it is a measure of how much the user application can store the number of indicators FA-TB161ACC2.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words FA-TB161ACC2. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FA-TB161ACC2 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FA-TB161ACC2&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Conversion module
FA-TB161ACC2
MITSUBISHI Conversion module FA-TB161ACC2
Can e isolated from the output of the p
MITSUBISHI
Conversion module
FA-TB16XY2N
MITSUBISHI Conversion module FA-TB16XY2N
Convert connector to screw relay termina
MITSUBISHI
Conversion module
FA-TB1L32XY
MITSUBISHI Conversion module FA-TB1L32XY
The connector is converted to a screw re
MITSUBISHI
Conversion module
FA-TB18XY
MITSUBISHI Conversion module FA-TB18XY
Can e used as a screw relay terminal.