MITSUBISHI F9GT-HCAB3-150
NTSC/PAL output system.
Applicable model: A985GOT-V. Input and output points: 24 points.
Power supply: AC100-240V.
Input points: 14 points.
Output points: 10 points.
Output form: relay output.
Power consumption: 32W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
EEPROM memory cartridge with program transfer function .
Third generation standard model F9GT-HCAB3-150.
Easy to use integrated models and flexible scalability F9GT-HCAB3-150
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps F9GT-HCAB3-150.
Auxiliary relay: 7680 points .
Timer: 320 points.
Counter: 235.
Data register: 8000.
Extended register: 24000 point.
Extended file register: 24000.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application F9GT-HCAB3-150.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points. Analog input channel number: 4CH.
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: none.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Reduce the incidence of non qualified products by inhibiting the effect of external interference,
Improve the efficiency of life and product quality by using external interference suppresssion function,
The temperature fluctuation caused by external disturbance can be rapidly attenuated,
To ensure that the product processing within the specified temperature range, reduce the incidence of substandard products F9GT-HCAB3-150.
This function is very eefffective for the product packaging machine and injection molding machine, the semiconductor manufacturing device of the wafer heating board and so on F9GT-HCAB3-150.