Input: 6 channels.
200/100/10kpps.
Counter input signal: 5VDC.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control AJ35TB1A-8R.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge
AJ35TB1A-8R
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment AJ35TB1A-8R. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency) AJ35TB1A-8R.
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders . (QD65PD2)Motor series: low inertia, small capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.6kw.
Rated speed: 3000rpm.
With a brake band.
Shaft end: straight shaft.
AC servo motor and brushless DC servo motor in the function of the difference: AC servo is better, because it is a sine wave control, torque ripple small.
DC servo is a trapezoidal wave. DC servo is simple and cheap. Type: sensor connector (e-CON).
Input form: DC input, positive pole common end.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 3 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distribbuted input and output deevices AJ35TB1A-8R.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastterr) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station AJ35TB1A-8R.
AJ35TB1A-8R Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=AJ35TB1A-8R&select=5