Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input .
Heating wire break, SSR fault detection function: 1 points D4GL-2AFG-A.
Communication: RS-485
D4GL-2AFG-A
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications D4GL-2AFG-A.
E5AC white LCDPV display height is about 25mm .
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications D4GL-2AFG-A.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Type: open type.
Structure: bottom mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except foor the 300/600/1500W outpput terminals)
Support finger touch protection to prevent electric shock D4GL-2AFG-A.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer D4GL-2AFG-A. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
D4GL-2AFG-A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4GL-2AFG-A&select=5