Operation: Push operation, Self-reset; Pull operation, Hold.
Built-in Switch: V-15-1B6.
Door Switches with Built-in Basic.
Switches for Long Life.
Installation in electrical facilities, equipment doors, and other,
openings helps ensure safety by reliably preventing accidents.
A Basic Switch if built in to provide a large switching capacity,
and long service life CRT1-AD04. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor
CRT1-AD04
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Rated voltage: 100 V CRT1-AD04.
Permitted voltage fluctuation range: 85% to 110% rated voltage .
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.180 A; 60 Hz, 0.150 A .
Rated input: 50 Hz, 14 W ; 60 Hz, 12 W .
Rated rotational speed: 50 Hz, 2400 r/min; 60 Hz, 2800 r/min.
Maximum flow rate: 50 Hz, 1.9 m3/min; 60 Hz, 2.2 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 42.2 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 43 dB CRT1-AD04.
Optimum Cooling with a Comprehensive .
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. External power supply: 12 VDC.
Output type: Contact and NPN transistor output.
Supply voltage: 24 VAC/12 to 24 VDC.
1-stage.
DIN 72 × 72 mm Multifunction Counter with a,
Bright, Easy-to-view, Negative Transmissive LCD.
Highly visible display with backlit transmissive LCD.
Selectable display color (red/greenn) enables checking output status at a distance CRT1-AD04.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter,
and tachometer (See note.).
Wide range of inputs accepted for NPN/PPNPP inputs (multi-inputs) and,
2-wire DC sensors CRT1-AD04.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only).
CRT1-AD04 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CRT1-AD04&select=5