Product name: AC Power Supply Unit.
Power supply voltage: 100 to 240VAC.
Output capacity: 5-VDC output capacity, 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, Yes.
Standards: UC1, N, L, CE .
Equipped with the RUN output for,
checking the operation status,
as well as the replacement
C200H-FZ001
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options C200H-FZ001. No. of poles: 5.
Connection method: Screw-on.
Suitable cable dia: 8 mm (7 to 8).
Core conductor size: 0.18 to 0.75 mm.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors C200H-FZ001.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock .
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alterrnate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV C200H-FZ001.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs C200H-FZ001.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
C200H-FZ001 Operation manual/Instructions/Model selection sample download link: