Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness B3J-3000.
Three-color models (green, orange, red; chameleon lighting)
B3J-3000
included in lineup. Classification: Exclusive Models.
Description: Double-element model.
Temperature range (See note 3.): -196°C to 250°C.
Element type: Pt100.
Conductor type: Two 3-conductor systems.
Class: B.
Protective tubing material: ASTM316L.
Terminal type: Exposed lead wires B3J-3000.
Page: 27 .
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal B3J-3000. Free change detection direction.
Easy to use small cube type.
Can change the direction of detection according to the position of the front and side (15 degree).
Type: cube detection variable way / DC type connector.
Shape: shield.
Detection distance: 20mm.
Output status: NO+NC NPN (two kinds of output). Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV B3J-3000.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation B3J-3000.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
B3J-3000 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=B3J-3000&select=5