Cable: PVC.
Cable core number: 3.
Cable outlet direction: L type.
Cable length L:2m.
Small round type waterproof connector.
Small waterproof connector can meet the requirement of protection IP67.
Is the ideal choice for a variety of FA and QA applications.
As with connector cable products, so no need for wiring operation . Output: SPDT.
Lighting: LED B3F-1075.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2
B3F-1075
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch B3F-1075.
The same contacts can be used for both standard loads and microloads .
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models B3F-1075. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked eeasily because operation time,
is indicated from the start of operation B3F-1075.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeenccy, basic,
frequency, and load conditions B3F-1075. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
B3F-1075 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=B3F-1075&select=5