Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 49 (65).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor A3PJ-90A21-24EGR.
Problems such as the collision of workpieces are eliminated
A3PJ-90A21-24EGR
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Model: C500-CPU11-EV1.
C500-CP CPU CPU MODULE JAPANESE C500-CPU11-EV1Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6 A3PJ-90A21-24EGR. 4 dia. .
Protective tubing length L: 20cm .
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal A3PJ-90A21-24EGR. Appearance: Round/Projection type LED voltage-reduction lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer A3PJ-90A21-24EGR.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication A3PJ-90A21-24EGR.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
A3PJ-90A21-24EGR Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3PJ-90A21-24EGR&select=5