Safety outputs: --.
Safety standstill detection output: 3.
Auxiliary output: 2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standstill is monitored by the motor''s back electromotive force (BEMF) signal .
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment A3KJ-90D1-24ER.
"User Configuration" also available for fine-tuning of sensitivity
A3KJ-90D1-24ER
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified. I/O classification: Input and output.
Internal I/O circuit common: PNP (input: – common; output: + common) A3KJ-90D1-24ER.
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available A3KJ-90D1-24ER.
Downsizing enabled with 32-point MIL connector for I/O connection .
Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternatte,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV A3KJ-90D1-24ER.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs A3KJ-90D1-24ER.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A3KJ-90D1-24ER Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3KJ-90D1-24ER&select=5